Rotor Pump Selection: How to Choose the Right Daikin RP

Rotor Pump Selection: How to Choose the Right Daikin RP
What to put in a quote request
Facebook
Twitter
Reddit
LinkedIn

Rotor pump selection comes down to four decisions, taken in order. Fix the duty point, match it to an RP frame, choose the pressure code and motor together, then choose the control method and check the installation envelope.

Most rotor pump selection errors are not the wrong size. They are the right frame with the wrong pressure code, or the right code on a motor that does not support it, because the RP model string packs frame, control, pressure range, motor output, voltage, and mounting into one line.

This guide walks through the four decisions using the Daikin RP series, the integrated rotor pump most machine-tool builders ask about, and the Daikin RP catalogue as the source for every limit quoted here. If you want the construction first, see what a hydraulic rotor pump is. If you already know the family and want the range, the Daikin RP series page lists the frames and control options.

Key Takeaways

  • Start from flow at the working pressure, not from frame size. Four RP frames cover 8.0 to 37.7 cm³/rev, with 60 Hz flow ranges from 4.8 to 64.0 L/min.
  • The pressure code and motor are chosen together: for A control, code 3 (21 MPa) without a remote valve is offered only on RP15 at 2.2 kW, RP23 at 3.7 kW and RP38 at 5.5 kW.
  • The digits after the dash are motor output, not pressure. RP15A1-22-30 is a 7 MPa build; RP15A3-22-30 is the 21 MPa version of the same frame and motor.
  • Choose A control for one holding pressure, and C control for a cycle that approaches at low pressure and holds at high pressure, with H (pressure feedback) or J (solenoid) as the switch.
  • Check the envelope before ordering: petroleum oil only, ISO VG 32 to 68, NAS class 9, suction at -16.7 kPa or above, case pressure 0.1 MPa or less, and vertical mounting only on RP08 and RP15 with the T suffix.

Rotor pump selection starts with the duty point

Rotor pump selection starts with the duty point
Rotor pump selection starts with the duty point

A selection begins with a short list of numbers, not a model number. Each one removes a group of frames or rules out a control type.

Item Unit Why it matters
Required flow at working pressure L/min The frame must contain this inside its adjustment range, not just reach it at cutoff
Working pressure MPa Sets the pressure code, and the code sets which motor you may order
Peak or relief pressure MPa Must sit under the code ceiling with margin for setting tolerance
Duty cycle Description One pressure, or two per cycle; the second favours C control
Supply voltage and frequency V, Hz The flow column is a 60 Hz figure, and 50 Hz delivers less
Mounting Foot or vertical Vertical is restricted to two frames and needs a rigid base
Fluid and ambient ISO grade, °C Petroleum oil only, ambient ceiling 40 °C

The pump creates flow; the circuit creates pressure. A machine that needs 40 L/min at 18 MPa needs a pump that holds 40 L/min while the load is at 18 MPa, not one whose nameplate range merely includes 40 somewhere. The pressure-flow curves, drawn at 100, 150 and 200 percent of rated current, are where that check happens. The hydraulic pump sizing guide covers the flow, displacement, and power arithmetic.

Because the RP is pressure compensated, a duty point taken at the relief valve setting is the wrong place to measure it. Below the set pressure, the pump delivers its adjusted flow; as pressure approaches the setting, the compensator reduces displacement, and at cutoff the flow falls close to zero while pressure holds. Measure at the pressure the machine actually works against.

Step 1: Match the frame to the flow range

Daikin builds four RP frames, each with a fixed displacement, a set of motor options, and a flow column that is an adjustment range rather than a rating. Daikin describes the series as rotor pumps that integrate an electric motor with an internal piston mechanism, built around low noise, a compact design, low pulsation, and high reliability, with consideration for CE compliance (official product page).

Frame (displacement) Motor Max pressure with the right code Flow at 60 Hz Mass
RP08 (8.0 cm³/rev) 0.75 kW 14 MPa 4.8 to 14.0 L/min 30 kg
RP15 (14.8 cm³/rev) 1.5 kW 14 MPa 12.0 to 25.0 L/min 45 kg
RP15 (14.8 cm³/rev) 2.2 kW 21 MPa 12.0 to 25.0 L/min 45 kg
RP23 (24.4 cm³/rev) 2.2 kW 14 MPa 20.0 to 42.0 L/min 67 kg
RP23 (24.4 cm³/rev) 3.7 kW 21 MPa 20.0 to 42.0 L/min 73 kg
RP38 (37.7 cm³/rev) 3.7 kW 14 MPa 20.0 to 64.0 L/min 73 kg
RP38 (37.7 cm³/rev) 5.5 kW 21 MPa 20.0 to 64.0 L/min 87 kg

Read the third column as a ceiling, not a promise. It is the highest pressure available on that frame and motor when the pressure code allows it. The 1.5 kW RP15, the 2.2 kW RP23, and the 3.7 kW RP38 stop at 14 MPa because code 3 is not offered on those pairings for A control. The RP08 stops at 14 MPa in every build.

The flow column is also narrower than it looks. Those are adjustable ranges, and the top of each sits close to what the displacement delivers at a four-pole motor’s speed at 60 Hz. For the RP08, 8.0 cm³/rev at about 1,750 rpm is 14.0 L/min, exactly the top of its range. A duty near the top leaves little room, and a duty near the bottom may sit below the recommended setting, because the catalogue advises setting the discharge rate to no lower than two-thirds of maximum, or suction capacity may be insufficient.

Two frame rules sit outside the table. The RP08 has restrictions when used between 7 and 14 MPa. And the C control in step 3 is not offered on the RP08 at all.

A larger frame is not automatically safer. A 32 L/min duty fits both the RP23 and the RP38, but the larger pump runs closer to the bottom of its range, where the adjustment screw is turned further in, and suction margin is thinner. Choose the smallest frame that contains the duty with room to set the screw sensibly, then check the curve.

Step 2: Choose the pressure code and motor together

Step 2: Choose the pressure code and motor together
Step 2: Choose the pressure code and motor together

Most selection errors start here, because the digit that sets pressure and the digits that set motor output sit a few characters apart in the same string. On an A-control pump, the pressure code is the single digit between the control letter and the dash:

Code A control, no remote valve A control, with remote valve Meaning in the string
1 1.5 to 7 MPa 2.0 to 7 MPa Compensator tops out at 7 MPa
2 1.5 to 14 MPa 2.0 to 14 MPa Compensator tops out at 14 MPa
3 3.5 to 21 MPa 2.0 to 21 MPa Compensator tops out at 21 MPa

A remote relief valve raises the floor of the range: the same code 1 pump begins at 2.0 MPa instead of 1.5, with the ceiling unchanged. The motor is the two digits after the dash, where 07 is 0.75 kW, 15 is 1.5, 22 is 2.2, 37 is 3.7, and 55 is 5.5, all four-pole.

Now the coupling. For A control without a remote valve, code 3 is offered only on three pairings: RP15 with 2.2 kW, RP23 with 3.7 kW, and RP38 with 5.5 kW. That is why the table in step 1 shows 21 MPa only on the larger motor of each frame. Choosing 21 MPa is also choosing more motor, more mass and a different build.

Three decodes make the rule concrete:

  • RP15A1-22-30 is an RP15 with A control, pressure code 1, and a 2.2 kW motor. It is a 7 MPa build. The “22” is the motor.
  • RP15A3-22-30 is the same frame and motor with code 3. It is the 21 MPa build, and it is legal because code 3 on the RP15 requires the 2.2 kW motor.
  • RP23A3-37-30 is a 21 MPa RP23 with the 3.7 kW motor. Its 2.2 kW sibling, RP23A2-22-30, stops at 14 MPa.

Consider what that means in a quote. A buyer who reads “22” as the pressure ceiling and orders RP15A1-22-30 for an 18 MPa circuit has ordered a pump whose compensator cannot reach 18 MPa at all. The motor is the larger unit, so the price and mass look right and the error only appears at commissioning. The reverse happens too: ordering the RP38 on its 3.7 kW motor for a 20 MPa duty, when that build is capped at 14 MPa.

If pressure must be adjustable from a remote station, the catalogue recommends a JR-G(T)02 or JRP-G02 relief valve. Leaving the vent port blocked defeats pressure compensation, and the pump runs at a fixed pressure.

Step 3: Choose the control method for the machine cycle

Control is the decision buyers skip most often, and it is the one that changes the pump count.

A control is a pressure compensator with one setting: the pump delivers its flow until pressure reaches the setting, then trims flow to hold it. A-RC is the same, but with a remote setting. C control gives two settings, one low and one high, and switches between them, using CH pressure feedback or CJ solenoid. Both deliver high flow at low pressure and low flow at high pressure, the profile of a cycle that approaches fast and then holds hard.

Model High flow at 60 Hz Low flow at 60 Hz Motor Mass, H / J
RP15C-15 12.0 to 25.0 L/min 3.5 to 10.0 L/min 1.5 kW 50 / 52 kg
RP15C-22 12.0 to 25.0 L/min 3.5 to 10.0 L/min 2.2 kW 50 / 52 kg
RP23C-22 20.0 to 42.0 L/min 3.7 to 15.0 L/min 2.2 kW 70 / 72 kg
RP23C-37 30.0 to 42.0 L/min 5.8 to 25.0 L/min 3.7 kW 76 / 78 kg
RP38C-37 30.0 to 64.0 L/min 5.8 to 25.0 L/min 3.7 kW 76 / 78 kg
RP38C-55 30.0 to 64.0 L/min 5.8 to 25.0 L/min 5.5 kW 90 / 92 kg

Two readings matter. The C models are listed at 21 MPa maximum, and the high-range digit sets the actual ceiling rather than the table’s headline. And the high range can be restricted by the low-range setting, which the catalogue shows on its setting graphs, so a wide low-to-high split is not always available at full high flow.

The factory settings are a starting point, not a specification. Daikin sets the low-flow screw at 2 degrees on the RP15C-15, 4 on the RP15C-22, 2 on the RP23C-22, 3 on the RP23C-37, 3 on the RP38C-37, and 5 on the RP38C-55, with scale ranges that differ by frame, and the high-flow setting ships at maximum. Adjusting either screw changes the pair, so both settings belong in the commissioning record.

Consider a press cycle that approaches at 7 MPa and holds at 18 MPa. With A control, the pump holds 18 MPa throughout, so the approach runs at the higher pressure and heats the oil. With C control, the low range covers the approach at high flow and the high range covers the hold at low flow, and one pump replaces two.

C control has limits. It is not offered on the RP08. It adds mass: the RP23C-22 is 70 kg with pressure feedback and 72 kg with the solenoid, against 67 kg for the A-control RP23 on the same motor. And the pair of settings must be commissioned, not assumed.

Step 4: Check the installation envelope

Step 4: Check the installation envelope
Step 4: Check the installation envelope

A rotor pump selection can pass the first three steps and still fail at installation. The catalogue publishes these limits (GK247D pages C-2 to C-4).

Check Catalogue limit Where it bites
Fluid Petroleum-based R&O or wear-resistant oil, ISO VG 32 to 68, 15 to 400 mm²/s, 0 to 60 °C, water 0.1% or less Non-petroleum fluids are prohibited, so biodegradable and fire-resistant fluids are out
Cleanliness NAS class 9 or better Dirt reaches the piston group and bearings; the same oil cools the motor
Suction -16.7 kPa or higher A restricted suction line causes cavitation, noise, and damage
Return filtration 25 µm or better, 10 µm or better at 14 MPa and above The high-pressure builds need the finer filter
Case drain 0.1 MPa or less, pipe 1 m or less, below oil level, separate from other returns A shared or long drain raises case pressure and pushes oil past the seals
Ambient -20 to 40 °C, 95% RH or less, 4,000 m or less The motor is oil-cooled, so hot ambient raises oil temperature
Mounting Four foot holes, filler at the top, level Out-of-level mounting puts the oil where it should not be
Vertical option RP08 and RP15 only, with the T suffix, on a rigid base The rubber pad does not work vertically; the base must absorb vibration
Fill volume 1,100 cm³ (RP08), 2,300 (RP15), 4,500 (RP23-22), 4,000 (RP23-37), 4,000 (RP38) The case must be filled with the circuit fluid at start-up
Electrical Four-pole motor, Type B insulation, terminal box IP54, EN60034-1 Fit a no-fuse breaker and a ground fault interrupter, and ground the unit

Flanges are not included. The catalogue supplies piping flanges separately, so they belong on the order rather than on the assumption list.

Overload headroom is finite. The catalogue rates 150 percent of rated current as continuous operation and 200 percent as momentary, which is why the curves are drawn at those currents. A duty that only works at 150 percent has no margin for voltage sag, and the thermistor setting is taken from the 150 percent current with an allowance for supply fluctuation.

The case runs hot. Surface temperature can reach about 80 °C, which is a guarding and labelling question rather than a pump question.

Start-up has a sequence. Fill the case, set the discharge rate to at least two-thirds of maximum, bleed air by switching the motor on and off, and if pressure does not rise within five minutes, swap two of the three phases. A pump that will not build pressure on first start is usually running backwards.

Rotor pump selection examples: three duty points

These are illustrative duty points, not customer installations. Each ends at a starting model plus the check that must follow. The full specification tables are in the GK247D catalogue pages C-5 to C-19.

Example A, a small clamp unit. Duty: 10 L/min at 6 MPa, one holding pressure, foot mount, 200 V at 60 Hz. Six MPa fits pressure code 1 (1.5 to 7 MPa), and 10 L/min fits the RP08 range of 4.8 to 14.0 L/min, so the starting model is RP08A1-07-30: 8.0 cm³/rev, 0.75 kW, 30 kg. At 6 MPa, the RP08’s 7 to 14 MPa restriction does not apply. The remaining check is the RP08-07 curve at 6 MPa, to confirm the 0.75 kW motor holds the duty near the top of the range.

Example B, a press power unit. Duty: 60 L/min at 18 MPa, one holding pressure, foot mount. Eighteen MPa needs code 3, and 60 L/min fits the RP38 range of 20.0 to 64.0 L/min. Because code 3 without a remote valve requires the 5.5 kW motor on this frame, the starting model is RP38A3-55-30: 37.7 cm³/rev, 5.5 kW, 21 MPa, 87 kg.

The 3.7 kW RP38 stops at 14 MPa and is not a candidate. The remaining check is the RP38-55 curve, because 60 L/min sits near the top of the range and delivered flow at 18 MPa will be lower than the no-load figure.

Example C, a two-pressure cycle. Duty: 30 L/min at 7 MPa for approach, then 18 MPa hold, one pump. C control fits: low range code 1 covers the 7 MPa approach, and high range code 3 covers the 18 MPa hold. The RP23C-22 carries 20.0 to 42.0 L/min high and 3.7 to 15.0 L/min low, so a 30 L/min approach and a hold of 15 L/min or less fit inside the table. The starting model takes the form RP23C13H-22-30: 2.2 kW, pressure feedback, 21 MPa maximum, 70 kg.

The remaining check is the C-control setting graph, because the low-range setting can restrict the high range.

In all three, the model string starts the quote request rather than ending the selection. Mark the duty point on the pressure-flow curve for the chosen frame and motor, then confirm the build against that frame’s catalogue table.

What to put in a quote request

What to put in a quote request
What to put in a quote request

A supplier who receives a full model string and a duty point can confirm or correct it in one pass. Send six things:

  1. The model string, as far as you have it, including control letter, pressure digits, motor digits, voltage code, and any RC or T suffix.
  2. The duty point: flow at working pressure, and the peak pressure if it differs.
  3. The supply: voltage and frequency, phase, and the protection you have.
  4. The mounting: foot or vertical, and if vertical, confirmation that the base is rigid.
  5. The fluid and ambient: the oil, its ISO grade, and the ambient range.
  6. The cycle: one pressure or two, and if two, the flow and pressure at each stage.

The string does not carry everything. It says nothing about the discharge-rate setting, the oil grade, port options, whether a remote relief valve is fitted, or whether flanges are in scope. Those five items are the ones most often missing from a first order, and each can stop a start-up.

The string also should not be asked to carry a price, a stock position, or a delivery date, which depend on the build and the market at the time. The selection ends with a build that matches the duty, and the commercial conversation starts there.

Frequently asked questions

How do I choose between RP08, RP15, RP23 and RP38?

Start with the flow range that contains your duty at the working pressure: 4.8 to 14.0 L/min for the RP08, 12.0 to 25.0 for the RP15, 20.0 to 42.0 for the RP23, and 20.0 to 64.0 for the RP38 at 60 Hz. Then check that the pressure you need is available on a motor the frame offers. The RP08 stops at 14 MPa and has no C control.

What does the number after the dash mean?

It is the motor output in kilowatts times ten, so RP15A1-22-30 has a 2.2 kW motor. Pressure is the digit before the dash, so that string is a 7 MPa build, and RP15A3-22-30 is the 21 MPa version of the same frame and motor. Reading the “22” as pressure is the most common model-code error.

Do I need A control or C control?

Choose A control when the machine holds one pressure, and add a remote valve if that pressure must be adjustable away from the pump. Choose C control when the cycle approaches at low pressure and holds at high pressure, and you want one pump instead of two. C control is not available on the RP08 and adds a few kilograms of mass.

Can I run an RP on a 50 Hz supply?

Yes, but the flow will be lower, and the catalogue’s flow column is a 60 Hz adjustment range. Use the 50 Hz pressure-flow curve for the frame and motor you are considering rather than scaling the 60 Hz figure. The motor is four-pole, so a lower supply frequency means a lower shaft speed and less displacement per minute.

What oil and filtration does a Daikin RP need?

Petroleum-based R&O or wear-resistant hydraulic oil, ISO VG 32 to 68, viscosity 15 to 400 mm²/s and fluid temperature 0 to 60 °C, with water at 0.1 percent or less by volume and contamination NAS class 9 or better. Fit a 150 mesh suction filter and a return filter of 25 µm or finer, or 10 µm or finer at 14 MPa and above. Non-petroleum fluids are prohibited.

Can a Daikin RP be mounted vertically?

Only the RP08 and RP15, and only with the T suffix. The catalogue notes that the rubber mounting pad has no effect vertically, so the base must be rigid and able to absorb vibration. The larger frames are foot-mounted only.

Conclusion: rotor pump selection in four steps

Rotor pump selection is a sequence, and the sequence is what keeps a correct-looking model string from becoming a failed start-up. Fix the duty point at the working pressure, put it inside a frame’s 60 Hz flow range with room to set the discharge screw above two-thirds, choose the pressure code, then check that the motor the code requires is one the frame offers. Decide between A and C control from the machine cycle, then run the envelope check on oil, filtration, suction, case drain, mounting, and electrical protection.

A buyer who follows those steps arrives at a model string they can defend, and a supplier can confirm it without redoing the work. The Daikin rotor pump range is the place to compare frames, and the catalogue values here are the ones to quote back when you ask for a build. If you are still deciding whether an integrated rotor pump is the right family, the comparison of rotor pumps and vane pumps covers that question.

Contact us right now!

Understand Loyal
Recently Posted
Contact Form Demo
Scroll to Top